Voges-Proskauer Test

 

 

To perform this test in VUMIE Online© Online Lab , complete the following steps:

 

Inoculation of Medium

1. Select the MRVP broth medium.  

2. Complete the process of a tube-to-tube aseptic transfer to inoculate the medium.  Forgotten how to do these things?  Watch the "Show Me How To" videos.

 

Incubation of the Inoculated Medium

3. Place the inoculated tube into the 35-37 C incubator.  

  4. Press the New Day button to move forward 24 hours.  Forgotten how to do these things?  Watch the "Show Me How To" videos.

 

Addition of Reagents

5. Incubate this test for only 24 hours.  

6.  Retrieve the incubated culture from the incubator.

7.  This is a test that requires addition of reagents to bring about the change in appearance of a positive test. 

 

 

 

Select the dropper tool and the appropriate reagent needed from the chemical shelf. Remove the cap.  For this test, select   Barritt's A add it, and then add Barritt's B.

 

 

 

Determination of Test Results

 8. Observe test result. For this test, addition of the appropriate reagents makes the culture turn red if the test is positive. If negative, no color change is observed.  

 9. Record test result.